The elevator malfunction is not always due to mechanical wear or aging. There are multiple potential causes, and maintenance personnel must identify the specific type of fault before proceeding with repairs. This paper focuses on electrical faults in elevators, their causes, and troubleshooting techniques.
1) **Door Interlock Failure**: The safe operation of an elevator relies heavily on the automatic door opening and door interlock system. If this system fails, the elevator cannot operate normally. Faults often arise from poor contact, misadjustment, or damaged wiring in components like the automatic door lock.
2) **Circuit Issues**: In control circuits composed of relays and contactors, faults commonly occur at contacts. Arcing can damage contacts, leading to short circuits or open circuits. Dust accumulation, broken springs, or damaged reeds may also cause similar issues if not addressed promptly.
3) **Insulation Failure**: Over time, electrical components and circuits may experience insulation breakdown due to aging, moisture, or external forces. This can result in system disconnections or short circuits.
4) **Electromagnetic Interference (EMI)**: With the increasing use of micro-control systems in elevators, EMI has become a growing concern. Sources include temperature, humidity, vibration, grid fluctuations, and inverter interference. To reduce such issues, elevators should use a three-phase five-wire power supply, separating the protective earth (PE) from the neutral (N) to prevent stray currents from disrupting the control system.
5) **Component Damage or Misalignment**: Damage, improper adjustment, or resonance in electronic components, circuit boards, or control systems can lead to elevator malfunctions. These issues often require careful inspection and replacement.
**Troubleshooting Techniques**:
1) **Program Inspection**: Follow the standard elevator operation sequence—selection, direction, closing, starting, acceleration, running, leveling, opening, and stopping. Identifying where the process breaks down helps narrow down the issue.
2) **Resistance Measurement**: Use a multimeter to check resistance values in the circuit when power is off. This helps detect faulty components or poor connections.
3) **Potential Measurement**: Measure the voltage across components while the system is powered. A deviation from expected values indicates a problem.
4) **Short-Circuit Method**: Temporarily short-circuit suspected contacts to see if the fault disappears. This method works only for AND logic contacts and must be used carefully to avoid short circuits.
5) **Open Circuit Testing**: Disconnect suspected sections of the circuit to isolate the fault. If the issue resolves, it confirms the location.
6) **Replacement Method**: Replace suspected faulty components or boards. If the problem is resolved, the faulty part is identified.
7) **Testing for Poor Contacts**: Use a voltmeter, thermometer, and low-voltage high-current test to detect loose or corroded connections. High voltage readings at certain points indicate poor contact.
In summary, electrical faults in elevators are complex and require a systematic approach. Maintenance personnel should combine technical knowledge with practical experience to quickly and accurately resolve issues. Understanding the root cause is essential for effective troubleshooting.