Fitted Target Efficacy metric promotes discussion

The FTE metric for outdoor luminaires was a major topic for discussion during a Webcast by the DOE's Energy Star program, which is itself a target for the EPA, writes Brian Owen.

Pole-mounted luminaires: draft criteria On October 9, the US Department of Energy (DOE) conducted a Webcast to explain the process and progress of Energy Star for SSL Outdoor luminaires. Entitled “Hitting the Target: Energy Star SSL Outdoor Area Lighting” the Webcast was moderated by Kelly Gordon of Pacific Northwest National Laboratory (PNNL) featured PNNL's Jason Tuenge, who presented the status of the Energy Star criteria and the new metric, Fitted Target Efficacy (FTE).
The slides from the presentation can be found here, and the comments submitted during the initial commentary period can be found here .
At the recent IES Street and Area Lighting Conference in Philadelphia, Tuenge presented an update an the new metric, reassuring the audience that the DOE had listened to the comments submitted from the industry during the commentary period and that the DOE had made modifications and is proposing Revisions that reflected these comments where applicable and necessary.
As a review, Tuenge explained that this is an addition to applications for Energy Star Category A and that the draft criteria was first released on July 1st, 2009. These new applications include Pole-mounted area and roadway luminaires, including decorative and historic, but Excluding bollards which are already covered in Version 1.1. Also included are Wall-mounted area luminaires or “wall packs” and Ceiling-mounted garage and canopy luminaires, but excludes step lights.
Tuenge addressed why it was determined to add these applications, stating that this is a very active area of ​​the SSL market, there is a high level of interest from energy-efficiency programs, municipalities, and other stakeholders noting that CALiPER testing has revealed a wide Range of performance and Demonstration projects indicate potential for large energy savings and most importantly the need for performance guidelines.
Questions regarding ceiling-mounted criteria were addressed and no revisions are proposed. With respect to wall-mounted criteria, the uplight allowances will be eliminated.
Pole-mounted luminaires
Pole-mounted criteria prompted the majority of comments and discussion. Tuenge firstly addressed the IES new luminaire classification system, or the BUG (Backlight, Uplight, Glare) rating system, explaining that FTE evaluates backlight and uniformity. When asked why wasnt BUG incorporated in Its comment and the Lighting Zones are not addressed, the response was that Lighting Zones and BUG ratings cannot be addressed independent of the specific project. A comment received was that the uplight restrictions were too lenient as upward light is wasted and contributes to sky glow and Recommendation revision eliminates uplight allowances.
Tuenge presents the new pole-mounted FTE metric, which is project-independent, summarizing that it determines the Uniform Pool of illumination unique to each luminaire and sums the luminous flux landing therein, fits a Rectangular Target to surround the Uniform Pool and finds the % The summed boundaries are scaled (down) by the % coverage and then divided by input wattage (lm/W).
Tuenge cited the benefits as; application-independent; allows for the evaluation of efficacy (lm/W); measures the effectiveness of house-side (HS) shielding; uses distribution shape; and, there are no arbitrary proportions. He noted that there Is flexible for designers and manufacturers, and that effective HS shielding is rewarded, but not required. Also, area of ​​coverage is described, not prescribed, and there is an "apples-to-apples" comparison for similar distributions, independent of MH and Illuminance.
Tuenge covered the "how to" of FTE product evaluation by firstly importing IES format absolute-photometry data file into software already developed by DOE and then reviewing the software output.
Comments and responses
One comment considered consideration of site-specific requirements when establishing criteria, ie required illuminance, roadway width and lighting power density (LPD). The response was that site-specific criteria cannot be addressed at the luminaire-qualification level and that appropriate luminaires should be Selected by qualified designers. The response to a comment that it would be overly selective to expect LED to outperform 75th percentile HID by 20% was that a proposed revision will reflect a reduction of requirements to the 75th percentile HID performance and that a Mid-Output Category will be created.
A comment that dimmable products may not meet requirements in one or more operating modes was addressed with a revision that include a clarification to the criteria sating that luminaires will be tested in their full-output mode. The response to a comment that some distributions are designed For lateral asymmetry and would be unfairly penalized was that the algorithm will be revised and simplified to eliminate the requirement for symmetry. It was noted that FTE is not intended to evaluate luminaires designed for Small Target Visibility (STV).
The response to a comment that the metric should benefit larger areas of coverage was that large area of ​​coverage can reduce initial system cost and embodied energy, but ongoing energy consumption, being the bulk of life-cycle impact, remains the primary concern of Energy It was asked as to whether Target Efficacy Rating (TER) as defined in NEMA LE 6-2008 was considered? The response was that TER was evaluated but not adopted because neither uniform meaning nor distribution of distribution was evaluated and due to improper treatment of A possible revision, to include to 1.0-MH for Types II-III-IV, would be a major improvement and that a NEMA vote was scheduled for October 7th and that results of the vote are awaited.
Questions and answers
Induction was troubled between inductive and broad pole spacing or shielding on the house side and In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In In Such as TM-21 is the standardized forecasting of depreciation through heat-sinking at it is recommend that it be included in warranties and the CCT lower limit is set to 2700K, as per definition in ANSI C78.377. The FTE metric provides delivered hences To the target in a useful manner, delivered to uniform pool as compared to the battery lumens baseline, of which HID is the baseline technology.
Earlier in the presentation, Tuenge discussed the FTE software and a question was raised that there was difficulties in its employment. Tuenge stated that properly formatted IES files should only be used with the software and that any errors are usually related to non-standard or poor Formatting. He advised participants that should they encounter any problems, they could send him their photometric file and he could likely correct the issue easily and quickly for them. Asked about the BUG rating system, the relative detail can be found in IES TM-15 -07, Addendum A.
Tuenge was asked as to whether the issue of IR radiation into the sky from the heat sink been considered and he responded that he doesn't think that it is substantial but they (the DOE) will look into it.
Tuenge commented that the Energy Star criteria is setting a reasonable bar of quality with LED not achievable with competing technology. There must have been a few competing technology proponents participating as 2 separate questions were asked about the eligibility of HID The response being that scope of the criteria is for LED only.
A number of questions were asked about correlations and dependence, such as 'Does FTE depend on mounting height? with the response being no with respect to uniformity and the uniform pool in relation to MH, the relationship is preserved. It was also asked if There was a correlation between FTE and LPD and Tuenge responded that there was no strong correlation, further stating that is was expected and fundamental that the luminaire will be applies by a designer.
Tuenge responded to question regarding the inclusion of additional specifications for controls such as dimming, stating that although the benefits are recognized, it is best evaluated at a project level and considered separately. Asked whether there would be a category for luminaires with integral controls, Tuenge Responded that the problem is the site-specific nature or requirements, which are not clear-cut, therefore would not be incorporated into specifications.
When asked about IES involved in the development of the criteria, Tuenge noted that the IES has been involved throughout the process and that there is a close working relationship between the DOE and the IES. The Roadway Lighting committee of the IES may have had a different Opinion going into this process, but hopefully with most of the comments addressed, there will be a general satisfaction with the criteria. At a recent RLC meeting, held typically after the IES Street and Area Lighting Conference, this year in Philadelphia, the RLC Is also hard at work getting the long overdue revision of the RP-8 'Recommended Practice for Roadway Lighting' into publication and practice, including the new BUG luminaire classification system. A question was posed as to whether there has been any field verification of the FTE metric. Tuenge's short answer was that FTE is relatively new and no, but in checking the results of GATEWAY Demonstrations, there has been good correlation between FTE and perf Ormance in the project depending as whether or not the selected luminaire is well suited for the project. Asked if other metrics were considered, such as the NEMA TER, the answer was yes, but TER didnt fit requirements and that FTE is a better metric for the Purpose of the criteria.
Dark skies and dark days for DOE
As described in a recent LEDs Magazine article , the International Dark-Sky Association (IDA) raised alarms regarding bluish-white light. Tuenge commented that the DOE is aware of the concerns and that it is an ongoing area of ​​research, admitting that more research Is required but that it is not currently something that can be directly applied to lighting practice. Tuenge also commented, "We (the DOE) dont feel that it is something to cause alarm."
In addition to the Webcast subject, another target was hit in recent days, as the DOE Energy Star program became the target of the Environmental Protection Agency (EPA) ? see News . Richard Karney, DOE Energy Star Program Manager answered a question posed, explaining That is hoped that this criteria will be finalized within 4-6 weeks and then handed over to EPA for implementation.
Conclusions
I asked Shirley Coyle, President of Ruud Lighting Canada (BetaLED) for her comments on the webcast. "Jason Tuenge of PNNL did a good job of explaining why they have decided to use the FTE (Fitted Target Efficacy) metric for achievement of Energy Star For LED outdoor lighting. "The Coyle, adding "The FTE metric is an improvement over the simplistic and sometimes misleading LPW (lumens per watt) efficacy rating because it goes beyond LPW to evaluate the LED luminaire's ability to linearly distribute light to a target area . . . . . . . . . . . Energy efficient and functionally effective." Coyle was one of many industry professionals who were originally quite sceptical about the 'efficacy' of the metric itself, but with the prope r application and consideration or limited revisions, has seen where the metric can be beneficial.
When asked as to the difficulty for a manufacturer meeting Energy Star criteria for Outdoor Luminaires, Coyle commented, "Achieving Energy Star will not be a short putt for SSL luminaire manufacturers. The standard has been written to assure that any LED luminaire making the cut is Able to compete against the cream of the crop in today's current HID luminaires, the top 25% of incumbent HID technology.” Noting “At BetaLED / Ruud Lighting, we certainly believe LED lighting can earn its place on a project based on competing against best -in-class HID systems."
At the conclusion, Tuenge noted that the DOE would determine if a 2nd comment outlook might be necessary. About the Author Brian Owen, a contributing editor of LEDs Magazine , is also the Program Advisor to greenTbiz, which facilitates the LED City Toronto initiative. He Is actively involved in the development and operation of energy conservation programs for government, municipalities and utilities and specializes in capacity building, commercialization and market transformation. greenTbiz, an ENERGY STAR, Lighting Facts and L Prize Partner, provides energy conservation and environmental awareness programs to The small business sector in Toronto, Canada.